DH1020 Insertion type electromagnetic flow meter
Reliable, High Accuracy Flowmeter for Food, Beverage and Pharmaceutical Applications.
Feature:
1.Smart design, enabling display of medium flow direction and empty tube
2.signal;
3.Two styles featured: compact and separate type;
4.Coming available in multiple models, such as tube-shaped and insertion model.
Powered by AC or DC in smart way, in two-wire mode, or using lithium cell
5.Wide flow range (30:1) and low initial flow rate for measurement (0.2m/s);
6.Adoption of EEPROM, ensuring impregnably secure storage of measurement & calculation data;
7.Displaying second, minute, hour, day, month and year;
8.Equipped with the communication interface RS-485 compatible with the protocol
MODBUS and the HART compatible communication interface;
9.Simplified and tested structure; without movable parts and no intercepting or choking parts,
thereby guaranteeing absence of pressure loss or fluid blockage;
10.Nonexistence of mechanical inertia leading to rapid response and excellent stability; capable
of being applied in automatic detection, adjustment and program control system;
11.Accuracy in measurement not subject to the kind, temperature, viscosity, density, pressure and
other physical properties of the medium;
12.l Diverse mixes of polytetrafluoroethylene or rubber linings and electrode materials
(e.g. Hc, Hb, 316L and Ti etc.) adapting the product to various media;
13.l Suitable for measuring a variety of corrosive fluids, including strong acid, strong alkali, and
saline solution etc.;
Data sheet
<
Technical Performance Parameters |
Caliver |
DN3~DN3000mm |
Nominal Pressure |
0.6~4.0MPa(special pressure can be made to) |
Accuracy |
±0.5%,±0.3%or±0.2% are selectable |
Liner material |
Teflon,PFA,F46,Neoprene,Polyurethane |
Electrode Type |
General type ,scraper type and replaceable type |
Electrode material |
Stainless steel SUS316,Hastelloy C,Titanium,Tantalum Platinum-iridium,Stainless steel covered with tungsten carbide |
Medium Temperature |
Integral type |
-20°C~+60°C |
Remote type |
Neoprene & Polyurethane Liner |
-10°C~+80°C |
PTFE Liner /PFA Liner /F46 Liner |
-10°C~+160°C |
Ambient Temperature |
-25°C ~+ 60°C |
Ambient Humidity |
5~100%RH(relative humidity) |
Medium Electrical conductivity |
≥20μ s/cm |
Measuring Range |
1500:1,flow rate<15m/s |
Structure type |
Integral type,remote type,submersible type,ex-proof type |
Protection Class |
IP65,IP68(optional) |
Ex-proof Mark |
ExmdⅡT4 |
Product Standard |
JB/T 9248-1999 Electormagnetic Flowmete |
Model pictures:
|