DH1010 romote control type flowmeter magnetic
Reliable, High Accuracy Flowmeter water Applications.
Feature:
1.Smart design, enabling display of medium flow direction and empty tube
2.signal;
3.Two styles featured: compact and separate type;
4.Coming available in multiple models, such as tubeshaped and insertion model.
Powered by AC or DC in smart way, in two-wire mode, or using lithium cell
5.Wide flow range (30:1) and low initial flow rate for measurement (0.2m/s);
6.Adoption of EEPROM, ensuring impregnably secure storage of measurement &
calculation data;
7.Displaying second, minute, hour, day, month and year;
8.Equipped with the communication interface RS-485 compatible with the protocol
MODBUS and the HART compatible communication interface;
9.Simplified and tested structure; without movable parts and no intercepting or choking parts,
thereby guaranteeing absence of pressure loss or fluid blockage;
10.Nonexistence of mechanical inertia leading to rapid response and excellent stability;
capable of being applied in automatic detection, adjustment and program control system
11.Accuracy in measurement not subject to the kind, temperature, viscosity, density, pressure
and other physical properties of the medium;
12.Diverse mixes of polytetrafluoroethylene or rubber linings and electrode materials
(e.g. Hc, Hb, 316L and Ti etc.) adapting the product to various media;
13.Suitable for measuring a variety of corrosive fluids, including strong acid, strong alkali,
and saline solution etc.;
Structure:
Data sheet
<
Technical Performance Parameters |
Caliver |
DN3~DN3000mm |
Nominal Pressure |
0.6~4.0MPa(special pressure can be made to) |
Accuracy |
±0.5%,±0.3%or±0.2% are selectable |
Liner material |
Teflon,PFA,F46,Neoprene,Polyurethane |
Electrode Type |
General type ,scraper type and replaceable type |
Electrode material |
Stainless steel SUS316,Hastelloy C,Titanium,Tantalum Platinum-iridium,Stainless steel covered with tungsten carbide |
Medium Temperature |
Integral type |
-20°C~+60°C |
Remote type |
Neoprene & Polyurethane Liner |
-10°C~+80°C |
PTFE Liner /PFA Liner /F46 Liner |
-10°C~+160°C |
Ambient Temperature |
-25°C ~+ 60°C |
Ambient Humidity |
5~100%RH(relative humidity) |
Medium Electrical conductivity |
≥5μ s/cm |
Measuring Range |
1500:1,flow rate<15m/s |
Structure type |
Integral type,remote type,submersible type,ex-proof type |
Protection Class |
IP65,IP68(optional) |
Ex-proof Mark |
ExmdⅡT4 |
Product Standard |
JB/T 9248-1999 Electormagnetic Flowmeter |
Model pictures: